Skip to content

Resources

What a rental house needs to read in a rider to quote accurately the first time, section by section.

Updated:

A rider is a specification, not a wish list. The clearer it is about quantities, formats and schedule, the fewer assumptions end up in the quote. This is the order we read one in.

1. Project basics

  • Venue, room and city. Include the load-in route if you know it: dock, freight lift, stairs.
  • Dates and times for load-in, rehearsal, show and load-out, not just the show day.
  • Audience size and layout: theatre, banquet, standing, in the round.
  • Who we report to on site, and who approves substitutions.

2. Audio

  • Coverage, not just a box count: room dimensions or a drawing, and the level and bandwidth the programme needs. Speech reinforcement and a live band are different systems.
  • Console model or minimum channel count, and whether a guest engineer brings a show file.
  • Input list and stage plot, with microphone models where they matter.
  • Monitoring: wedges, in-ear systems, number of independent mixes.
  • Wireless: channel count for microphones and in-ears. Radio spectrum differs by country, so say which frequency ranges your own units use if you are bringing any.

3. Video

  • Screen size in metres and aspect ratio. For LED, the pixel pitch or the closest viewing distance. For projection, front or rear and how much ambient light to expect.
  • Every source and its format: laptops, playback, cameras, remote guests. State resolution and frame rate.
  • Destinations: main screen, confidence monitors, relay screens, recording, stream.
  • Switching: number of layers, picture-in-picture, whether you need a specific switcher family because your operator knows it.

4. Lighting

  • A plot if one exists. If not, describe the job: stage wash for cameras, audience light, effects, architectural.
  • Fixture types and quantities, console model, and whether haze is permitted in the venue.
  • Who programs and who operates.

5. Rigging, staging and power

  • Flown or ground-supported, trim heights, and the venue's point loads if you have them. Rigging is never assumed available.
  • Stage dimensions, height, risers, stairs, ramp.
  • Power: what the venue provides and where. Mexico supplies 127 V single-phase and 220 V three-phase at 60 Hz, which matters for equipment arriving from 230 V / 50 Hz countries.

6. Crew

List the roles you want us to supply and the ones you bring. State working language, call times and whether operators are needed for rehearsals as well as the show.

7. Substitutions

Mark each line as exact, preferred or equivalent accepted. A rider where everything is exact is slower and more expensive to fulfil; a rider where nothing is marked leaves the choice to the supplier.

Most common omissions: load-in and load-out times, the stream or recording requirement, power, and the name of the person who can approve a change.

← All resources